Intended Audience: Engineers, Technologist, Technicians, Students

PDH UNITS: 6

Here we deal with the protection & control principles of high voltage stations. HV Bus Differential Protection is studied along with restrictions due to CT saturation & mismatch and its solution, “Restraint Differential Protection”. Starting with System Faults and how they affect Switchyard Configuration & Elements simple “Differential Protection” is examined along with the mal-operation due to CT saturation and mismatch. High Voltage Circuit Breakers are examined as to the various Types (Oil, Vacuum, Air Blast, SF6), their Controls (Closing/Tripping/anti-pumping) Reclosure Syncrocheck relay CUH 90 – VG, as well as Breakers Failure Protection, is part of this module along with a quick look at Dynamic Monitoring Equipment. Transfer & remote tripping along with the need to provide immunity from ground rise potential and open-circuit situations. Duration: 5hr 23min of video content Prerequisites: A solid background in electrical circuitry.

Learning Objectives:

At the successful conclusion of this course, you will learn the following knowledge and skills: Here we deal with the protection & control principles of high voltage stations.
  • HV Bus Differential Protection is studied along with restrictions due to CT saturation & mismatch and its solution, “Restraint Differential Protection”.
  • System Faults; Switchyard Configuration & Elements;
  • The DESN Station (Dual Element Spot Network);
  • HV Bus Differential Protection; CT Saturation & Mal-operation of Bus Protection;
  • CT Saturation & Restraint Differential Protection; Westinghouse KD - 4 Relay; Surge Protective Devices;
  • Fuses; DC Protection; Logic Differential Protection;
  • The Modern IED Relays (Intelligent Electronic Device); Overview HV Circuit Breaker Types (Oil, Vacuum, Air Blast, SF6);
  • HV Circuit Breaker Controls (Closing & Tripping);
  • HV Circuit Breakers; Reclosing (Syncrocheck CUH 90 – VG Relay);
  • Dynamic Monitoring Equipment (DME); Impedance Relaying (POTT)

Prime PDH Day is back with TWO days to save big. Prime PDH sale starts Tuesday July 16 and Ends Wednesday July 17 11:59 pm, 2024.
Buy any Online Course or Webinar NOW and save 50% - as many as you need
No Limits - No Restrictions
Discount Code: PRIME24
https://nciteengineeringhub.com/

Please Join us for our next live interactive presentation tomorrow (Wednesday, 6/5, 2pmET).
https://nciteengineeringhub.com/course/live-webinar-essentials-of-photovoltaic-system-design/

ACCEPTANCE GUARANTEE


ncees

Ncite Engineering Hub engineering courses & live webinars meet NCEES Guidelines for Professional Engineer licenses renewal in all 50 states.

Ncite Engineering Hub will refund your money if the PDH credits you earn are rejected by your state board for any reason.

top
Copyright 2019 · All Rights Reserved. Ncite Engineering Hub, LLC 513 E- Main Street # 981 Charlottesville, VA 22902 USA