E – 1286 Sound Level Data for Mechanical and Electrical Equipment

$75.00

This publication contains sound pressure and sound power data for mechanical equipment commonly found in many commercial buildings. Where possible, the noise data have been correlated with some of the more obvious noise influencing parameters, such as type, speed, power rating, and flow conditions. The noise levels quoted in this publication are suggested for design uses; these noise levels represent approximately the 80 to 90 percentile values. That is, on the basis of these sample sizes, it would be expected that the noise levels of about 80 to 90 percent of a random selection of equipment would be equal to or less than the design values quoted in the manual, or only about 10 to 20 percent of a random selection would exceed these values. This is judged to be a reasonable choice of design values for typical uses. Higher percentile coverage, such as 95 percent, would give increased protection in the acoustic design, but at greater cost in weight and thickness of walls, floors, columns, and beams. On-site power plants driven by reciprocating and gas turbine engines have specific sound and vibration problems, which are considered separately elsewhere.

Course Outline
1. INTRODUCTION
2. SOUND PRESSURE AND SOUND POWER LEVEL DATA
3. PACKAGED CHILLERS WITH RECIPROCATING COMPRESSORS
4. PACKAGED CHILLERS WITH ROTARY-SCREW COMPRESSORS
5. PACKAGED CHILLERS WITH CENTRIFUGAL COMPRESSORS
6. BUILT-UP REFRIGERATION MACHINES
7. ABSORPTION MACHINES
8. BOILERS
9. STEAM VALVES
10. COOLING TOWERS AND EVAPORATIVE CONDENSERS
11. PUMPS
12. FANS
13. AIR COMPRESSORS
14. RECIPROCATING ENGINES
15. GAS TURBINE ENGINES
16. ELECTRIC MOTORS
17. STEAM TURBINES
18. GEARS
19. GENERATORS
20. TRANSFORMERS
21. OPENING IN A WALL
22. GLOSSARY

This is an introduction to noise characteristics and noise control for mechanical and electrical equipment.

SKU: E - 1286 Categories: , ,

Description

This publication contains sound pressure and sound power data for mechanical equipment commonly found in many commercial buildings. Where possible, the noise data have been correlated with some of the more obvious noise influencing parameters, such as type, speed, power rating, and flow conditions. The noise levels quoted in this publication are suggested for design uses; these noise levels represent approximately the 80 to 90 percentile values. That is, on the basis of these sample sizes, it would be expected that the noise levels of about 80 to 90 percent of a random selection of equipment would be equal to or less than the design values quoted in the manual, or only about 10 to 20 percent of a random selection would exceed these values. This is judged to be a reasonable choice of design values for typical uses. Higher percentile coverage, such as 95 percent, would give increased protection in the acoustic design, but at greater cost in weight and thickness of walls, floors, columns, and beams. On-site power plants driven by reciprocating and gas turbine engines have specific sound and vibration problems, which are considered separately elsewhere.

Course Outline
1. INTRODUCTION
2. SOUND PRESSURE AND SOUND POWER LEVEL DATA
3. PACKAGED CHILLERS WITH RECIPROCATING COMPRESSORS
4. PACKAGED CHILLERS WITH ROTARY-SCREW COMPRESSORS
5. PACKAGED CHILLERS WITH CENTRIFUGAL COMPRESSORS
6. BUILT-UP REFRIGERATION MACHINES
7. ABSORPTION MACHINES
8. BOILERS
9. STEAM VALVES
10. COOLING TOWERS AND EVAPORATIVE CONDENSERS
11. PUMPS
12. FANS
13. AIR COMPRESSORS
14. RECIPROCATING ENGINES
15. GAS TURBINE ENGINES
16. ELECTRIC MOTORS
17. STEAM TURBINES
18. GEARS
19. GENERATORS
20. TRANSFORMERS
21. OPENING IN A WALL
22. GLOSSARY

This is an introduction to noise characteristics and noise control for mechanical and electrical equipment.

  • Learn the significant of A-weighted sound level measurements;
  • Learn the acoustic characteristics of packaged chillers with reciprocating compressors ranging in size from 15-ton to 200-ton cooling capacity;
  • Learn about the noise characteristics of rotary screw compressors;
  • Learn about sound characteristics of packaged chillers with centrifugal compressors;
  • Learn the noise control issues with steam and hot water boilers;
  • Learn how to control unwanted noise produced by cooling towers and evaporative condensers;
  • Learn how to calculate sound power levels for propeller-type cooling towers;
  • Learn the typical sound power levels for pumps;
  • Learn about the ASHRAE methods for estimating in-duct fan noise;
  • Learn noise control measures that can be applied to compressors, and
  • Learn how to control noise from electrical equipment such as generators and transformers.

Prime PDH Day is back with TWO days to save big. Prime PDH sale starts Tuesday July 16 and Ends Wednesday July 17 11:59 pm, 2024.
Buy any Online Course or Webinar NOW and save 50% - as many as you need
No Limits - No Restrictions
Discount Code: PRIME24
https://nciteengineeringhub.com/

Please Join us for our next live interactive presentation tomorrow (Wednesday, 6/5, 2pmET).
https://nciteengineeringhub.com/course/live-webinar-essentials-of-photovoltaic-system-design/

ACCEPTANCE GUARANTEE


ncees

Ncite Engineering Hub engineering courses & live webinars meet NCEES Guidelines for Professional Engineer licenses renewal in all 50 states.

Ncite Engineering Hub will refund your money if the PDH credits you earn are rejected by your state board for any reason.

top
Copyright 2019 · All Rights Reserved. Ncite Engineering Hub, LLC 513 E- Main Street # 981 Charlottesville, VA 22902 USA